XSA1000TG Series 10M RBW Spectrum Analyzer

XSA1000TG Series 10M RBW Spectrum Analyzer

+ Frequency Range from 9 kHz up to 3.6 GHz + 150dBm Displayed Average Noise Level + Phase Noise -82dBc/Hz @1Gz and offset at 10KHz + Total Amplitude Accuracy <1.5dB + 10Hz Minimum Resolution Bandwidth (RBW) + EMI Pre-compliance Test Kit + 1.5 GHz Tracking Generator Kit + 10.4 inches display...

Send Inquiry Chat Now

Product Details

+ Frequency Range from 9 kHz up to 3.6 GHz
+150dBm Displayed Average Noise Level
+相位噪声-82 dbc / Hz@1Gz and offset at 10KHz
+Total Amplitude Accuracy <1.5dB
+10Hz Minimum Resolution Bandwidth (RBW)
+EMI Pre-compliance Test Kit
+1.5 GHz Tracking Generator Kit
+10.4 inches display


Model Frequency Range RBW Phase Noise (Typical) TG Model
XSA1015 9kHz - 1.5GHz 10Hz - 3MHz <-80dBc/Hz@1GHz
XSA1036 9kHz - 3.6GHz 10Hz - 3MHz <-90 dBc/Hz@30 kHz offset


1. 10 Hz Minimum Resolution Bandwidth (RBW)
Digital IF technology offers a minimum bandwidth of 10Hz,allowing excellent signal resolution when separation of closely spaced signals is required.



Frequency Specification
Model XSA1015TG XSA1036TG
Frequency
Range 9kHz-1.5 GHz 9kHz - 3.6 GHz
Resolution 1Hz
Frequency span
Range 0 Hz,100 Hz to maximum frequency of device
Accuracy ± span /(swept points -1)
Internal reference
Reference frequency

10.000000 MHz

Temperature stability <2.5ppm (15℃ to 35℃)
Aging rate <1ppm/year
Bandwidth
Resolution bandwidth (-3 dB) 10Hz to 500kHz(in 1 to 10 sequence), 1MHz,3MHz
Video bandwidth (-3 dB) 10Hz to 3MHz
Amplitude Specification
Displayed average noise level(DANL)
Input attenuation 0 dB,1Hz resolution bandwidth
Preamp off 1 MHz~10 MHz -130dBm(nominated)
10 MHz~1GHz -130dBm(nominated)
1GHz~1.5 GHz -128 dBm( nominated )
Preamp on 1 MHz~10 MHz -150dBm(nominated)
10 MHz~1GHz -150dBm(nominated)
1GHz~1.5 GHz -148 dBm( nominated )
Phase noise
20 ℃ ~30 ℃,fc=1 GHz
Phase noise <-85 dBc/Hz @10 kHz offset
< -100年dBc / Hz @100 kHz偏移量
<-110 dBc/Hz @1 MHz offset
Level display range
Log scale coordinate 1dB ~255dB
Linear scale coordinate 0 to reference level
level unit dBm,dBuW,dBpW,dBmV,dBuV, W,V
Points 201~1001
Number of traces 5
Detectors Positive-peak, negative-peak, sample, normal, RMS
Trace functions Clear write, Max Hold, Min Hold, View, Blank, Average
Accuracy
Input Attenuation Switching Uncertainty 20℃ ~30℃, fc=50 MHz,Preamplifier Off, 20dB RF attenuation,input signal 0~39 dB
±0.5 dB
Absolute Amplitude Uncertainty 20℃ ~30℃, fc=50 MHz,RBW=1 kHz,VBW=1 kHz,peak detector, 20 dB RF attenuation,
Preamplifier Off ±0.4 dB,input signal= -20dBm
Preamplifier On ±0.5 dB, input signal= -40dBm
Uncertainty input signal range 0dbm~-50dbm
±1.5 dB
VSWR input 10 dB RF attenuation,1 MHz~1.5GHz
<1.5,nominal
Tracking generator
Output frequency range 100 kHz~1.5 GHz
Output power level range -30 dBm~0 dBm ,
Output power level resolution 1DB
Output flatness +/-3 dB
Maximum safe reverse level Average total power:30 dBm,DC : ±50 VDC
Inputs and Outputs
Front panel RF input connector 50 Ω,N-type female
Front panel track generator output 50 Ω,N-type female
10 M reference input 50 Ω,N-type female
Communication port USB Host, USB Device, LAN, earphone port, and VGA
General techincal specification
Display TFT LCD,10.4 inches
Weight 5.0 kg
Dimension (W x H x D) 321 x 221 x 115 (mm)




SUPPORT


▶ XSA1000 Series Spectrum Analyzer user manualxz.gif

▶ XSA1000 Series Spectrum Analyzer user Quick Guidexz.gif


ACCESSORIESThe accessories subject to final delivery.

2013827153299062.jpg

Power Cord

2013827154174210.jpg

CD Rom

2013827155525321.jpg

Quick Guide

2013827156225645.jpg

N-N Cable

(optional)

20176221033275833.jpg

N-SMA Cable

(optional)

20176221034166551.jpg

SMA-SMA Cable

(optional)

20176221034443897.jpg

SMA适配器

(optional)

20176221035243223.jpg

N-SMA Adaptor

(optional)

20176221036399204.jpg

Near Field Probe

(optional)





Inquiry